The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
Quantitation of polysorbate 80 in high protein formulation using solid-phase extraction (SPE) followed by derivatization with cobalt thiocyanate and UV measurement of the complex at 620nm resulted in lower recovery of polysorbate 80. Dilution of protein samples with water improved the recovery of polysorbate, however, it compromised the sensitivity of the method when cobalt thiocyanate was used for...
We developed a cancer chip by nano-patterning a highly sensitive SAM titanium surface capable of capturing and sensing concentrations as low as 10 cancer cells/mL from the environment by Matrix Assisted Laser Desorption and Ionization Time of Flight Mass Spectrometry (MALDI-TOF MS). The current approach evades any form of pretreatment and sample preparation processes; it is time saving and does not...
Previous applications of manganese(IV) as a chemiluminescence reagent have required the use of formaldehyde to enhance the emission intensity to analytically useful levels. However, this known human carcinogen (by inhalation) is not ideal for routine application. A wide range of alternative enhancers have been examined but to date none have been found to provide the dramatic increase in chemiluminescence...
We developed a novel and straightforward derivatization method for the determination of lactate by reversed phase high-performance liquid chromatography (RP-HPLC) with fluorescence and UV detection in biological matrices as urine and saliva. The derivatization of lactate was achieved employing 9-chloromethyl anthracene (9-CMA) as fluorescence reagent, which has never been previously used to obtain...
A novel fluorescence method for the determination of guanine was developed based on the fluorescence enhancement of Cu 2+ –nuclear fast red complex in the presence of guanine in Tris–HCl buffer. The complex of Cu 2+ with nuclear fast red resulted in a dramatic quenching of the fluorescence intensity. Nuclear fast red were dissociated from the complex with the addition of guanine due...
Gold nanoparticles (AuNPs) have been widely used to develop fluorescence resonance energy transfer (FRET) sensors to detect biological substances, environmental pollutants, and disease markers due to their superior quenching capacity to fluorescence signals. In this study, we report the one-step facile synthesis of fluorescein isothiocyanate-labeled hyaluronic acid (FITC–HA) functionalized fluorescent...
DNA adducts represent an important category of biomarkers for detection and exposure surveillance of potential carcinogenic and genotoxic chemicals in the environment. Sensitive and specific analytical methods are required to detect and differentiate low levels of adducts from native DNA from in vivo exposure. In addition to biomonitoring of environmental pollutants, analytical methods have been developed...
In this work, the electrodeposition of pyrocatechol violet (PCV) was initially investigated by the electrochemical surface plasmon resonance (ESPR) technique. Subsequently, PCV was used as redox-mediator and was electrodeposited on the surface of pencil graphite electrode (PGE) modified with single-wall carbon nanotubes (SWCNTs). Owing to the remarkable synergistic effect of SWCNTs and PCV, PGE/SWCNTs/PCV...
Poly(brilliant green) (PBG) and poly(thionine) (PTH) films have been formed on carbon film electrodes (CFEs) modified with carbon nanotubes (CNT) by electropolymerisation using potential cycling. Voltammetric and electrochemical impedance characterisation were performed. Glucose oxidase and uricase, as model enzymes, were immobilised on top of PBG/CNT/CFE and PTH/CNT/CFE for glucose and uric acid...
A fraction collector based on a drop-on-demand ink-jet printer was developed to interface capillary zone electrophoresis with a 96 well microtiter plate. We first evaluated the performance of the collector by using capillary zone electrophoresis to analyze a 1mM solution of tetramethylrhodamine; a fluorescent microtiter plate reader was then used to detect the analyte and characterize fraction carryover...
Perfluorocarbon (PFC) compounds have been used as chemical tracer molecules to understand the movement of supercritical carbon dioxide for geosequestration monitoring and verification purposes. A commonly used method for detecting PFCs involves the collection of a sample from either soil-gas or the atmosphere via carbon-based sorbents which are then analyzed in a laboratory. However, PFC analysis...
A simple pyrene based receptor has been synthesised and shown to exist in the dimeric form in solution exhibiting an excimer band in the emission spectrum. The proposed dimeric form is supported by the DFT calculations. Further, the excimer fluorescence is bathochromically shifted with decreased emission intensity in the presence of Hg 2+ suggestive of the formation of an aggregated complex...
A colorimetric mixed-pH dye-based indicator with potential for the development of intelligent packaging, as a “chemical barcode” for real-time monitoring of skinless chicken breast spoilage, is described. Also investigated was the relationship between the numbers of microorganisms and the amount of volatile compounds. This on-package indicator contains two groups of pH-sensitive dyes, one of which...
This study examines the utility of near infrared hyperspectral imaging (NIR-HSI) combined with chemometrics for the detection of dynamite residues on human handprints. Polyvinyl sheets containing dynamite residues were then analysed with the NIR-HSI system. A spectral library was developed by using partial least squares-discriminant analysis model (PLS-DA) to detect and classify the pixels contaminated...
The lipophilicity of untreated edible oils narrows the application of most published methods for the determination of antioxidant activity to hydrophilic extracts of oils.This research addresses the issue of the estimation of the total antioxidant properties of untreated edible oils by modifying two widely applied analytical methods, the Fe-Phenanthroline and the CUPRAC assays, to be used in untreated...
Novel class of active ionophores for surfactant selective electrodes is proposed. PVC membrane doped with polyelectrolyte–surfactant stoichiometric complex is used for ion-selective electrode construction responsive to cetyltrimethyl ammonium bromide and related surfactants. New ionophore is quite stable and completely insoluble in aqueous media in wide range of pH. The electrode displays nearly Nernstian...
Standard addition strips were prepared for the quantitative determination of caffeine in different beverages by electrostatic spray ionization mass spectrometry (ESTASI-MS). The gist of this approach is to dry spots of caffeine solutions with different concentrations on a polymer strip, then to deposit a drop of sample mixed with an internal standard, here theobromine on each spot and to measure the...
In this study, a simple, novel and efficient preconcentration method for the determination of some chlorobenzenes (monochlorobenzene (MCB), three isomeric forms of dichlorobenzene (diCB), 1,3,5-trichlorobenzene (triCB) and hexachlorobenze (hexaCB)) has been developed using a headspace solid phase microextraction (HS-SPME) based on nano-structured ZnO combined with capillary gas chromatography–mass...
A solid phase extraction (SPE) coupled with dispersive liquid–liquid microextraction based on the solidification of floating organic drop (DLLME-SFO) method, using diethyldithiphosphate (DDTP) as a proper chelating agent, has been developed as an ultra preconcentration technique for the determination of inorganic arsenic in water samples prior to graphite furnace atomic absorption spectrometry (GFAAS)...
Set the date range to filter the displayed results. You can set a starting date, ending date or both. You can enter the dates manually or choose them from the calendar.